2BV6-111 Liquid Ring Vacuum Pump in Refinery Flare Gas Recovery and Fuel Gas Systems

2026-11-25 13:32:37

Vacuum Requirements in Refinery Flare Gas Recovery

Refineries generate different types of low-pressure gas streams during crude oil processing, separation, storage, and other production operations. Some of these streams contain recoverable hydrocarbons that would otherwise be directed to the flare system. Recovering suitable gas streams can help reduce routine flaring, improve resource utilization, and support more efficient refinery gas management.

A flare gas recovery system typically collects gas from selected refinery sources and transfers it through separation, cooling, compression, and downstream treatment stages. Depending on the pressure conditions and system design, a liquid ring vacuum pump may be considered for auxiliary gas collection or vacuum-assisted recovery duties.

The 2BV6-111 liquid ring vacuum pump can be evaluated as part of a refinery gas recovery arrangement where its operating characteristics are compatible with the process gas and required suction conditions. Its potential role should be defined at the system-design stage rather than assumed to replace the main compressor or the complete flare gas recovery package.

Gas Collection and Pretreatment Configuration

Connection to Refinery Gas Collection Networks

The first stage of a flare gas recovery system involves collecting gas from designated process units, storage facilities, and low-pressure vent headers. These collection lines may carry hydrocarbon vapors together with moisture, condensable components, and occasional liquid carryover.

The 2BV6-111 may be integrated into an auxiliary vacuum line connected to a suitable gas collection header. Isolation valves, pressure monitoring points, and non-return devices can help manage gas flow and prevent unwanted backflow between connected process branches.

The collection network should be designed to avoid excessive pressure losses and maintain appropriate operating conditions across different gas sources. The actual connection point for the vacuum pump must be determined through process evaluation, including gas composition, pressure fluctuations, and the requirements of the downstream recovery equipment.

Inlet Separation and Liquid Carryover Control

Refinery gas streams may contain condensed hydrocarbons, water droplets, and other liquid contaminants. These materials should be managed before the gas reaches the vacuum pump.

An inlet separator or knockout vessel can be installed upstream to remove entrained liquids and collect condensate. Depending on the gas composition and process conditions, additional cooling or filtration equipment may also be required.

Proper separation helps protect the pump and reduce the risk of unstable operation caused by excessive liquid carryover. Drainage arrangements should provide controlled condensate removal while maintaining the integrity of the closed gas system.

Hydrocarbon Vapor Recovery and Gas Treatment

Managing Recovered Hydrocarbon Streams

Hydrocarbon vapor recovery requires coordination between gas collection, separation, and downstream treatment equipment. Depending on the refinery process, recovered gas may be routed to a fuel gas network, gas processing unit, or other suitable recovery facility.

The 2BV6-111 may serve as an auxiliary vacuum device in a compatible recovery configuration. Its connection with gas-liquid separators, cooling equipment, buffer vessels, and downstream treatment systems should be designed according to the actual process requirements.

Where condensable hydrocarbons are present, cooling and separation equipment can help collect liquid components before the remaining gas enters subsequent treatment stages. The recovered liquid should be directed to an appropriate collection or processing system rather than allowed to accumulate in the vacuum pipeline.

Gas Return and Backflow Prevention

Gas flow direction is an important consideration in refinery recovery systems. Check valves, isolation valves, and suitable control devices can help prevent reverse flow and unwanted communication between different gas sources.

The control system should coordinate the operating status of the vacuum pump with the conditions of the collection network and downstream equipment. Pressure monitoring and suitable interlocks can support controlled operation during startup, shutdown, and changes in gas supply.

Closed-Loop Operation and Working Liquid Management

Working Liquid Selection

Liquid ring vacuum pumps use a circulating working liquid to form the liquid ring and support the vacuum process. In refinery gas recovery applications, the working liquid must be selected according to the gas composition, process temperature, and potential chemical interactions.

Water may be suitable for certain gas streams, while other applications may require a different compatible working liquid. The presence of hydrocarbons, acidic components, or other contaminants should be evaluated before selecting the liquid and designing the circulation arrangement.

Gas-Liquid Separation and Cooling

A gas-liquid separator can be incorporated into the discharge side of the pump to separate the working liquid from the discharged gas. Depending on the system configuration, the working liquid may be cooled and recirculated through a closed-loop arrangement.

A complete package may include a separator, heat exchanger, circulation piping, make-up liquid connection, and temperature monitoring devices. These components help manage working liquid conditions and support stable system operation.

The discharge gas must also be routed to an appropriate downstream treatment or recovery point. It should not be released directly into the working environment.

Safety and Equipment Integration

Explosion Protection and Process Compatibility

Refinery flare gas and fuel gas streams may contain flammable hydrocarbons. Therefore, the suitability of the 2BV6-111 must be confirmed through a detailed review of gas composition, hazardous-area classification, electrical equipment requirements, sealing arrangements, and applicable explosion-protection standards.

A liquid ring design alone does not guarantee suitability for every flammable gas application. The pump, motor, instrumentation, piping, and auxiliary equipment must be evaluated as part of the complete system.

Integrated Control and Maintenance Planning

A refinery gas recovery package may combine the vacuum pump with inlet separators, condensers or coolers, gas-liquid separators, buffer vessels, valves, and a control cabinet. Coordinated control of these components helps manage gas collection, liquid removal, working liquid circulation, and downstream gas transfer.

Maintenance planning should also consider inspection access, condensate drainage, working liquid replacement, and isolation of individual equipment sections. These arrangements can support routine operation without compromising the integrity of the gas recovery network.

Conclusion

The 2BV6-111 liquid ring vacuum pump may be considered for auxiliary vacuum duties in compatible refinery flare gas recovery and fuel gas systems. Its potential integration with gas collection headers, inlet separators, cooling equipment, gas-liquid separators, and closed-loop working liquid systems can support a coordinated recovery arrangement.

Final equipment selection must be based on the actual gas composition, suction conditions, liquid carryover, working liquid compatibility, and explosion-protection requirements. A complete process and safety assessment is essential before applying the pump to a specific refinery flare gas recovery project.

 

   2bv6_grounded_800x800_3.jpg

vacuum pump  product   information

Web: http://www.greentechblower.com  (Group Web)  ‖  http://www.zqblower.cn  (Chinese)  ‖ http://www.ringblower.cn/ (Ring blower)  ‖  http://www.china-blower.com  (Roots Blower)  ‖  https://www.zibovacuumpump.com(Vacuum Pump)