Yes, absolutely. Because the 2RB 410-7AV25 (1AC) uses the surrounding air to cool its motor and relies on air density for its internal regenerative compression, high ambient temperatures directly reduce its efficiency and max pressure output.
When the intake air temperature rises, the air becomes less dense, meaning the blower has to work significantly harder to move the same mass of air. Furthermore, if the ambient temperature is too high, the motor’s internal cooling system cannot effectively dissipate the heat generated during 24/7 operation, leading to a performance "derating" where the unit automatically sacrifices pressure to avoid thermal failure.
Check Ventilation: Ensure your blower is not installed in an enclosed, unventilated cabinet where exhaust air is being recirculated back into the intake.
Monitor Surface Temp: If the blower casing exceeds 80°C during standard operation, you are likely losing 5–10% of your rated vacuum/pressure performance.
Use External Cooling: In hot factory environments, installing a simple auxiliary cooling fan to blow ambient air across the blower housing will instantly recover lost pressure performance.
Do you have more questions about the 2RB 410-7AV25 performance curves? Drop your specific environmental temperature below, and we will tell you exactly how much pressure you are likely losing!

ring blower product information
Web: http://www.greentechblower.com (Group Web) ‖ http://www.zqblower.cn (Chinese) ‖ http://www.ringblower.cn/ (Ring blower) ‖ http://www.china-blower.com (Roots Blower)
Copyright © 2025 Greentech International (Zhangqiu) Co., Ltd. | All Rights Reserved 鲁ICP备12007127号 Technical support:Xintuweb